Sign In | Join Free | My portofva.com
China Kingsine Electric Automation Co., Ltd. logo
Kingsine Electric Automation Co., Ltd.
Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing
Verified Supplier

17 Years

Home > CT Analyzer >

Current Transformer Test Set IEC60044-1 CT Analyzer KT210

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Current Transformer Test Set IEC60044-1 CT Analyzer KT210

Brand Name : Kingsine

Model Number : KT210

Certification : CE/ISO9001

Place of Origin : China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C,T/T

Supply Ability : 100 sets/month

Delivery Time : 15 working days

Voltage Range : 0~300V

Voltage Accuracy : ±0.1%

Size (W x H x D) : 360 x 140 x 325mm

Weight : <8 kg (without accessories)

Operating Temperature : -10°C up to + 55°C

Humidity : Relative humidity 5% up to 95% not condensing

Contact Now

Current Transformer Test Set IEC60044-1 CT Analyzer KT210

Description Of Current Transformer Analyzer

Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.

Feature Of Current Transformer Test Set

High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000).
It can test current transformer according to IEC60044-1, IEC60044-6, IEC61869-2 and ANSI30/45 standard etc.
Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.
PT Test As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT210 CT/PT Analyzer can also test them. KT210 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT.

Specification Of Current Transformer Test Device

Voltage Measurement Input
Secondary Input Range 0~300V
Max Knee point 30KV
Secondary Input Accuracy ±0.1%
Primary Input Range 0~30V
Primary Input Accuracy ±0.1%
Output
Output Voltage 0 Vac to 120 Vac
Output Current 0 A to 5 A (15 A peak)
Output Power 0 VA to 450 VA (1500 VA peak)
Main Power Supply
Input Voltage 176 Vac to 264 Vac @ 10A Max
Permissible Input Voltage 120 Vdc to 370 Vdc @ 5A Max
Frequency 50 / 60 Hz
Permissible Frequency 47 Hz to 63 Hz
Connection Standard AC socket 60320
Physical Dimensions
Size (W x H x D) 360 x 140 x 325mm
Weight <8 kg (without accessories)
Environment Conditions
Operating Temperature -10°C up to + 55°C
Storage Temperature -25°C up to + 70°C
Humidity Relative humidity 5% up to 95% not condensing

Advantage Of Current Transformer Test System

Easy to operate CT / PT Analyzer,
120V / 15A Current Output,
9.7 inch touch screen operation,
IEC60044-1, IEC60044-6, IEC61869-2, ANSI30/45 standard
High stability for bushing CT testing;

FAQ

Q: Can the device test the function of Synchronising or synchronism-check relays?

A: Yes.

Q: How about the guarantee of repair?

A: All of our products have 3-years guarantee of free repair, and life-long maintenance.

Q: What is your technical advantages?

A: Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.


Product Tags:

IEC 60044-1 CT Analyzer

      

IEC 61869-2 CT Analyzer

      

IEC 60044-1 Current Transformer Test Set

      
China Current Transformer Test Set IEC60044-1 CT Analyzer KT210 wholesale

Current Transformer Test Set IEC60044-1 CT Analyzer KT210 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Kingsine Electric Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)